| KC 2/15 | K 1/10 |
K 2/10 with steel crucible for lead melting
Observation hole for the melt
K 1/10 - K 4/13, KC 1/15 + KC 2/15
These compact melting furnaces for the melting of non-ferrous metals and alloys are one of a kind and have a number of technical advantages. Designed as tabletop models, they can be used for many laboratory applications. The practical counter balanced hinge with shock absorbers and the spout (not for KC) on the front of the furnace make exact dosing easy when pouring the melt. The furnaces are available for furnace chamber temperatures of 1000, 1300, or 1500 °C. This corresponds to melt temperatures of about 80-110 °C lower.
- Tmax 1000 °C, 1300 °C, or 1500 °C, with melt temperature about 80 - 110 °C lower
- Crucible sizes of 1, 2, or 4 liters
- Crucible with integrated pouring spout of iso-graphite included with delivery
- Spout (not for KC), mounted at the furnace for exact pouring
- Compact bench-top design, simple emptying of crucible by tiltiing system with gas damper
- Crucible for heating of furnace insulated with a hinged lid, lid opened when pouring
Additional Equipment
- Other crucible types available, e.g. steel or SiC
- Over-temperature limit controller with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the oven and melt The furnace shuts off upon overtemperature and switches back on when the temperature falls below the critical level.
- Observation hole for melt
| Model | Tmax | Crucible | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||
|---|---|---|---|---|---|---|---|---|---|
| °C | in L | W | D | H | power/kW | connection* | in kg | ||
| K 1/10 | 1000 | A 6 | 1,0 | 520 | 680 | 660 | 3,0 | single-phase | 85 |
| K 2/10 | 1000 | A10 | 2,0 | 520 | 680 | 660 | 3,0 | single-phase | 90 |
| K 4/10 | 1000 | A25 | 4,0 | 570 | 755 | 705 | 3,6 | single-phase | 110 |
| K 1/13² | 1300 | A 6 | 1,0 | 520 | 680 | 660 | 3,0 | single-phase | 120 |
| K 2/13² | 1300 | A10 | 2,0 | 520 | 680 | 660 | 3,0 | single-phase | 125 |
| K 4/13² | 1300 | A25 | 4,0 | 570 | 755 | 705 | 5,5 | 3-phase¹ | 170 |
| KC 1/15³ | 1500 | A6 | 1,0 | 580 | 630 | 580 | 10,5 | 3-phase | 170 |
| KC 2/15³ | 1500 | A10 | 2,0 | 580 | 630 | 580 | 10,5 | 3-phase | 170 |
| ¹Heating only between two phases *Please see page 50 for information on mains voltage ²External dimensions of furnace, transformer in separate housing (500 x 570 x 300 mm) ³Switchgear and controller mounted in a floor standing cabinet | |||||||||