| N 200/HDB |
N 300/HDB |
|
Preheated air is blown-in through perforated ceramic pipes
Exhaust gas outlet with motorized flap
- Horizontal injection of preheated air up to max. 500 °C, continuation of process up to sintering temperature with heating from five sides in the furnace
- Bottom heating protected by SiC heat-conducting plate (level stacking support)
- Separate exhaust gas/exhaust air outlets
- Automatic control of vapor vent flaps
- Exhaust hood in stainless steel 1.4301 (304)
- 2-Zone control, inlet air preheating as a second heat source is also separately controlled
- Temperature distribution better than ΔT 14 K during the debinding process and better than ΔT 20 K during the dwell time when sintering according to DIN 17052
- Safety system: monitoring of chamber pressure, inlet air and exhaust gas volume flow, emergency functions to avoid flammable mixtures in the furnace chamber
Additional Features
- Customized versions with respect to temperature and size
- Multi-zone control for processes requiring optimum temperature distribution
- Scales for measuring the weight loss during firing
- Thermal or catalytic exhaust gas cleaning
- Protective gas operation, e.g. for reduction of oxygen content in exothermic debinding
- Software for operation, process visualization and documentation
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Power | Supply | Weight |
| | °C | w | d | h | in L | W | D | H | kW | voltage* | in kg |
| N 200/DB | 1280 | 370 | 530 | 720 | 140 | 760 | 1045 | 1690 | 26 | 3-phase | 370 |
| N 300/DB | 1280 | 420 | 700 | 780 | 230 | 810 | 1215 | 1750 | 36 | 3-phase | 410 |
| N 450/DB | 1280 | 470 | 750 | 1000 | 350 | 1010 | 1440 | 1815 | 43 | 3-phase | 815 |
| | | | | | | | | | | | |
| N 200/HDB | 1340 | 370 | 530 | 720 | 140 | 790 | 1060 | 1690 | 31 | 3-phase | 420 |
| N 300/HDB | 1340 | 420 | 700 | 780 | 230 | 840 | 1230 | 1750 | 43 | 3-phase | 500 |
| N 450/HDB | 1340 | 470 | 750 | 1000 | 350 | 1120 | 1485 | 1825 | 53 | 3-phase | 1040 |
| | | | | | | | | | | | |
| N 200 /14HDB | 1400 | 370 | 530 | 720 | 140 | 790 | 1060 | 1690 | 33 | 3-phase | 450 |
| N 300 /14HDB | 1400 | 420 | 700 | 780 | 230 | 840 | 1230 | 1750 | 46 | 3-phase | 550 |
| N 450 /14HDB | 1400 | 470 | 750 | 1000 | 350 | 1120 | 1485 | 1825 | 53 | 3-phase | 1320 |
More information
Print
HT 64/16HDB - HT 276/17HDB
 |
|
| HT 64/17HDB |
|
- Horizontal injection of preheated air up to max. 500 °C, continuation of process up to sintering temperature with heating elements of molybdenum disilicide (MoSi2)
- Floor reinforcement with flat stacking support to protect fibre insulation and to support heavy loads
- Chain guided parallel moving swivel door for precise operation protecting the collar fibre insulation
- Door area amored with stainless steel to avoid burn damage
- Over temperature limit controller for product and furnace protection
- Furnace chamber lined with first-class, durable fibre materials
- Special ceiling construction with high durability
- Long lasting thermocouple, PtRh-Pt, Type B or Type S
- Separate exhaust gas and exhaust air flaps
- Automatic control of vapor vent flaps
- Exhaust hood in stainless steel 1.4301(304)
- 2-Zone control, inlet air preheating as a second heat source is also separately controlled
- Temperature distribution better than ΔT 14 K during the debinding process and better than ΔT 20 K during the dwell time when sintering according to DIN 17052
- Safety system: monitoring of chamber pressure, inlet air and exhaust gas volume flow, emergency functions to avoid flammable mixtures in the furnace chamber
Additional Features
- Customized versions with respect to temperature and size
- Multi-zone control for processes requiring optimum temperature distribution
- Scales for measuring the weight loss during firing
- Thermal or catalytic exhaust gas purification
- Protective gas operation, e.g. for reduction of oxygen content in exothermic debinding
- Software for operation, process visualization and documentation
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Power | Supply | Weight |
| | °C | w | d | h | in L | W | D | H | kW | voltage* | in kg |
| HT 64/16HDB | 1600 | 400 | 400 | 400 | 64 | 1020 | 840 | 1700 | 29 | 3-phase | 550 |
| HT 160/16HDB | 1600 | 500 | 550 | 550 | 160 | 1140 | 1020 | 1900 | 32 | 3-phase | 800 |
| HT 276/16HDB | 1600 | 500 | 1000 | 550 | 276 | 1140 | 1470 | 1900 | 49 | 3-phase | 1100 |
| | | | | | | | | | | | |
| HT 64/17HDB | 1750 | 400 | 400 | 400 | 64 | 1020 | 840 | 1700 | 29 | 3-phase | 550 |
| HT 160/17HDB | 1750 | 500 | 550 | 550 | 160 | 1140 | 1020 | 1900 | 32 | 3-phase | 800 |
| HT 276/17HDB | 1750 | 500 | 1000 | 550 | 276 | 1140 | 1470 | 1900 | 49 | 3-phase | 1100 |
More information