Korszerű anyagok

Chamber Furnaces for Processes with High Vaporization Rates of Organic Matter or for Thermal Cleaning by Ashing Electrically Heated or Gas-Fired

N 650/14 BO with ignition burner

The chamber furnaces of the model series N .. BO are used for processes with large amounts of organic matters or high vaporization rates. Processes in which the product or contaminations on the product are ashed by ignition can be also carried out safely in this type of furnace. Examples include residual wax removal of pouring clustersfollowed by sintering, or thermal cleaning of oxide catalytic honey combs from soot or fuel residues. The furnaces are electrically heated or gas-fired. The electrically heated furnaces, for safety reasons, are equipped with an integrated gas torch for igniting the flammable components in the gas mixture. The accumulation of flammable components is avoided and their safe combustion is ensured.

The furnace series is suitable for products that will not be damaged by a temporary, uncontrolled temperature rise.

The burning of unwanted organic ingrediants can take place at temperatures > 500 °C. Following this, a subsequent process can take place up to max. 1000 °C or 1400 °C (electrically) or 1000 °C (gas-fired).

For safety, the furnace door locks after the program was started and cannot be opened again until the temperature has dropped below a defined value. In case of burner malfunction or gas shortage the process is aborted.

Models N 100 BO - N 650/14 BO, electrically heated and gas fired ignition flame

  • Tmax 1000 °C or 1400 °C
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Exhaust hood
  • Fully automatic temperature control
  • Optional thermal afterburning
  • Ignition flame using natural gas or liquid gas (LPG)
  • Defined application within the constraints of the operating instructions

Models NB 300 BO and NB 650 BO, gas-fired

  • Tmax 1000 °C
  • Standard sizes up to 650 liters furnace chamber, additional sizes on request
  • Integrated thermal afterburning
  • Gas burners operating with natural gas or liquid gas (LPG)
  • Defined application within the constraints of the operating instructions
Model TmaxInner dimensions in mm Outer dimensions in mm Heating power
 °CwdhWDHin kW1
N 100 BO10004005304601200130021009
N 300 BO100055070078013501450220020
N 300/14 BO140055070078013501450220030
N 650/14 BO1400700850110017001900270062
1Depending on furnace design connected load might be higher
Model TmaxInner dimensions in mm Outer dimensions in mmOutput burner
 °CwdhWDHin kW
 
NB 300 BO1000550700780125016503000100
NB 650 BO10007008501100160021003150200