Professional Control and Documentation Alternatives
  
  

H 1700 with colored, tabular depiction of the data

H 3700 with colored graphic presentation of data

Temperature recorder

HiProSystems Control and Documentation

This professional control system for single and multi-zone furnaces is based on Siemens hardware and can be adapted and upgraded extensively. HiProSystems control is used when more than two process-dependent functions, such as exhaust dampers, cooling fans, automatic movements, etc., have to be handled during a cycle; when furnaces with more than one zone have to be controlled; when special documentation of each batch is required and when remote telediagnostic service is required. The system is also perfectly suited for controlling multiple furnaces or furnace groups. It is flexible and is easily tailored to your process or documentation needs.

  • Alternative User Interfaces
  • Touch panel H 700
  • This basic panel accommodates most basic needs and is very easy to use.
  • Touch panel H 1700
  • Firing cycle data and the extra functions activated are clearly displayed in a table. Messages appear as text.
  • Touch panel H 3700
  • All functions and process data are stored and displayed in easy to read charts. The data can be exported through various interfaces (RS 232, RS 422 /485, USB, Ethernet TCI/IP, MPI, Profibus) to a local PC or your company network for further processing. A CF card also gives the opportunity for data storage and transfer to a PC with a card reader.
  • Extension Package, PC-based for Control, Visualisation and Documentation Nabertherm Control Center NCC
  • Upgrading the HiProSystems-Control individually into an NCC provides for additional interfaces, operating documentation, and service benefits in particular for controlling furnace groups including charge beyond the furnace itself (quenching tank, cooling station etc.):
    • Recommended for heat treatment processes with extensive requirements in respect to documentation e.g. for metals, technical ceramics or in the medicine field
    • Software can be used also in accordance with the AMS 2750 D (NADCAP)
    • Documentation according to the requirements of Food and Drug Administration (FDA), Part 11, EGV 1642/03 possible
    • Charge data can be read in via barcodes
    • Interface for connection to existing Enterprise Database systems (e.g. SAP, Oracle)
    • Connection to mobile phone network for alarm message transmission via SMS
    • Control from various locations over the network
    • Calibration of each measuring point for a specific temperature possible
    • Extendable for calibration of a polygonal line with up to 18 temperatures per measuring point for use at different temperatures e.g for AMS 2750 D applications
Controltherm MV Software for Monitoring, Documentation and Control with Standard Controllers

Documentation and reproducibility gain increased attention with steadily rising quality standards. The powerful Nabertherm software Controltherm MV provides for an optimum solution for the control and documentation of one or more furnaces as well as charge data. This software is also perfectly suitable for retrofi tting in order to comply with new norms and directives.

Features

  • Simple installation without specific knowledge
  • All Nabertherm controllers with interface connectable
  • Temperature cycles of up to 16 furnaces (also multi-zone controlled) can be archived in manipulation-safe files
  • Redundant storage on a network server possible
  • Programming, archiving and printing of programs and graphics
  • Free input of descriptive charge data text with comfortable search function
  • Data exportable into Excel format for further evaluation
  • Start/stop of the controller from the local PC
  • 400 additional programs storable (only with Nabertherm controllers)
  • Connection of other furnaces/controllers by means of an additional temperature adapter possible and retrofittable
  • Extension of additional measuring points for archiving possible and retrofittable
Temperature Recorder

Reliable documentation method with a dot printer or continuous pen and up to six measuring points, also available with digitally storing graphic printer (e.g. CF card, USB-stick).