| S 250/65A | S 120/65A with protective gas retort box and cooling station next to the furnace |
Pit-type furnace S 250/65A with protective gas retort allowing bright annealing (see page 14)
S 30/65HA with exchangeable retort and two retort air cooling devices
S 30/45A - S 500/85A
Pit-type furnaces with air circulation offer the advantage of easy charging, for heat treatment of heavy parts or loads in charge baskets. With maximum application temperatures available from 450 °C to 850 °C, these compact furnaces are particularly useful for processes such as tempering, solution annealing, artificial ageing, and soft annealing.
- Maximum temperatures of 450 °C, 650 °C, 850 °C
- Air circulation fans in the furnace bottom, high circulation rate
- Vertical air circulation with square air heating chamber
- Optimum temperature uniformity (according to DIN 17052-1) up to ΔT 4 K
- Interior walls from stainless steel
- Switchgear with solid-state relays
Additional Equipment
- Charging hoist with swivel arm and charge basket
- Integrated fan for rapid cool down or separate cooling station for retort box cooling outside of the furnace
- Retort box with protective gas inlet and outlet for production in a defined atmosphere
- Manual or automatic gas supply systems
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Supply | Electrical | Weight | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| °C | w | d | h | in l | W | D | H | power/kW | connections* | in kg | |
| S 30/45A | 450 | 300 | 250 | 400 | 30 | 750 | 850 | 1250 | 3,6 | 1-phase | 130 |
| S 60/45A | 450 | 350 | 350 | 500 | 60 | 800 | 950 | 1350 | 6,6 | 3-phase | 225 |
| S 120/45A | 450 | 450 | 450 | 600 | 120 | 900 | 1050 | 1450 | 9,6 | 3-phase | 280 |
| S 250/45A | 450 | 600 | 600 | 750 | 250 | 1050 | 1200 | 1600 | 19,0 | 3-phase | 750 |
| S 500/45A | 450 | 750 | 750 | 900 | 500 | 1200 | 1350 | 1750 | 28,0 | 3-phase | 980 |
| S 30/65A | 650 | 300 | 250 | 400 | 30 | 750 | 850 | 1250 | 6,0 | 3-phase¹ | 130 |
| S 60/65A | 650 | 350 | 350 | 500 | 60 | 800 | 950 | 1350 | 9,6 | 3-phase | 225 |
| S 120/65A | 650 | 450 | 450 | 600 | 120 | 900 | 1050 | 1450 | 13,6 | 3-phase | 280 |
| S 250/65A | 650 | 600 | 600 | 750 | 250 | 1050 | 1200 | 1600 | 21,0 | 3-phase | 750 |
| S 500/65A | 650 | 750 | 750 | 900 | 500 | 1200 | 1350 | 1750 | 31,0 | 3-phase | 980 |
| S 30/85A | 850 | 300 | 250 | 400 | 30 | 600 | 740 | 1000 | 6,0 | 3-phase¹ | 130 |
| S 60/85A | 850 | 350 | 350 | 500 | 60 | 800 | 950 | 1350 | 9,6 | 3-phase | 225 |
| S 120/85A | 850 | 450 | 450 | 600 | 120 | 900 | 1050 | 1450 | 13,6 | 3-phase | 280 |
| S 250/85A | 850 | 600 | 600 | 750 | 250 | 1050 | 1200 | 1600 | 21,0 | 3-phase | 750 |
| S 500/85A | 850 | 750 | 750 | 900 | 500 | 1200 | 1350 | 1750 | 31,0 | 3-phase | 980 |
| ¹Heating only beetween two phases *Please see page 38 for more information about supply voltage | |||||||||||
catalogue Heat Treatment I
(URL: http://www.nabertherm.com/produkte/waermebehandlung/waermebehandlung_englisch.pdf)
catalogue Heat Treatment II