Additív gyártás /
Aknás retortakemencék 1100 °C-ig

Pit-Type Retort Furnaces up to 1100 °C

Retort furnace SRA 300/06 with charging basket Retort furnace SRA 200/09

Front made of textured stainless steel

The retort furnaces SR and SRA (with gas circulation) are designed for operation under non-flammable or flammable protective or reaction gases. The hot-wall retort furnaces are loaded from above by crane or other lifting equipment provided by the customer. In this way, even large charge weights can be loaded into the furnace chamber.

Depending on the temperature range in which the furnace be used, the following models are available:

Models SRA ../06 with Tmax 650 °C

  • Heating inside the retort
  • Gas-circulation with powerful fan in the furnace lid
  • Temperature uniformity up to +/- 5 °C inside the work space
  • Single-zone control
  • Retort made of 1.4571
  • Insulation made of high-grade mineral wool

Models SRA ../09 with Tmax 900 °C

  • Design like models SR…/06 with following differences:
    • All-around heating from outside of the retort
    • Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
    • Retort made of 1.4828

Models SR .../11 with Tmax 1100 °C

  • Design like models SR…/09 with following differences:
    • Without gas-circulation
    • Top down multi-zone control of the furnace heating
    • Retort made of 1.4841

Standard Equipment (all models)

  • Design like standard equipment of models NR and NRA with following differences: see control alternative page 71
    • Compact housing in frame construction with inserted stainless steel sheets
    • Charging from above with crane or other lifting equipment from customer
    • Hinged lid with opening to the side
    • Welded charging frame resp. gas-guiding box for furnaces with circulation
    • Gas-supply system for one non-flammable protective or reactive gas with flowmeter and magnetic valve
    • Furnace temperature control
    • Possible connection of an optional vacuum pump (for cold evacuation or for processes up to 600 °C under vacuum)
    • Defined application within the constraints of the operating instructions
    • NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
  • Additional equipment, H2 version or IDB version see models NR and NRA
ModelTmaxInner dimensions of alloy retortVolumeOuter dimensions1 in mmElectricalWeight
 °CØ in mmh in mmin lWDHconnection*in kg
SR(A) 17/.. 250350171300170018003-phase600
SR(A) 25/.. 250500251300190018003-phase800
SR(A) 50/.. 400450501400200018003-phase1300
SR(A) 100/..650,4008001001400200021003-phase1500
SR(A) 200/..9006007002001600220022003-phase2100
SR(A) 300/..or60010003001600220025003-phase2400
SR(A) 500/..110080010005001800240027003-phase2800
SR(A) 600/.. 80012006001800240029003-phase3000
SR(A) 800/.. 100010008002000260028003-phase3100
SR(A) 1000/.. 1000130010002000260031003-phase3300
SR(A) 1500/.. 1200130015002200280033003-phase3500
*Please see page 73 for more information about supply voltage
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.